The industrial ice machine needs regular maintenance to ensure the stable operation and long-term use of the equipment.

During the long-term use of the equipment in different environments (including harsh environments), the wear of mechanical parts, increased clearance, and changes in coordination will directly affect the original balance of the equipment. The stability, reliability, and use efficiency of the equipment will be reduced to a considerable extent, and even cause the mechanical equipment to lose its inherent basic performance and fail to operate normally.

In this way, the equipment needs to be overhauled or replaced, which undoubtedly increases the cost of the enterprise and affects the reasonable allocation of enterprise resources. Since the ice maker has a higher technical content than other refrigeration equipment, the quality of the ice maker's operating environment and regular maintenance are extremely important to the service life and ice making effect of the ice maker.

Now let's talk about the maintenance methods of tube ice machine.

Cleaning

Water tank cleaning

Both the water tank and the water pump should be kept clean without any accumulation of foreign matter. When sediments do occur (there is more accumulation of foreign matter or clay), the water tank should be thoroughly cleaned. If the machine is stopped for more than one day, the water tank should be cleaned once before restarting to ensure the quality of ice making. The specific cleaning steps are as follows:

1. Shut down and turn off the main power supply.

2. Release all the water in the water tank through the drain valve, and use detergent and a long-handled brush to clean the dirt in the water tank, and rinse with clean water several times until there is no dirt.

3. Inject new water to the liquid level when the float valve stops water supply and it can be turned on and used.

Evaporation tube cleaning

In the case of long-term use, a small amount of dirt may accumulate on the inner tube wall of the evaporation tube, which needs to be cleaned regularly. The frequency of cleaning depends on the water quality. In areas with hard water (the lime content in the local water is too high), it is necessary to clean once every 3-6 months, and in areas with normal or "soft" water, twice a year enough. The specific cleaning steps are as follows:

1. Release the water in the water tank first. Add clean water until the water tank is nine minutes full, and close the water supply valve. Add 2.1 liters of high-purity citric acid and mix it with water.

2. Turn off the refrigeration compressor and close the shut-off valve of the liquid line; turn on the water pump (in the absence of refrigeration) to run and circulate for about 2-3 hours. (Press "Start Cleaning" to clean; press "Stop Cleaning" to stop cleaning.)

3. After the sewage is released, inject new water and circulate for about 30 minutes. After cleaning the remaining detergent, release the second water. Cycle cleaning more than two times to ensure that the cleaning agent has been washed away.

4. Open the water supply valve and restore the refrigeration system to return the machine to normal operation. Inject new water to the level when the float valve stops supplying water and it can be turned on and used.

Water-cooled condenser cleaning

During the operation of the condenser, the cooling water will produce scale inside the pipe, which will affect the heat exchange effect. It should be cleaned frequently to improve the cooling efficiency. The frequency of cleaning depends on the water quality. In areas with extremely hard water, it is necessary to clean once every three months, while in areas with normal or "soft" water, it is only necessary to clean twice a year. The cooling system includes a cooling water tower and a water-cooled condenser, in order to make the machine run smoothly and ensure the service life of the machine. The cooling tower should also be cleaned in time to ensure the efficiency of ice making.

The specific cleaning steps are as follows:

1. Shut down and clean the cooling water tower with a brush first.

2. If the cooling tower is higher than the condenser, the cooling tower water should be drained first or the condenser and the cooling tower water inlet and outlet valves should be closed.

3. Open the drain valve under the end cover of the condenser to drain the water in the condenser.

4. Remove the end caps at both ends of the condenser. Clean each copper tube back and forth with a dedicated condenser brush, and then rinse it with water several times until it is clean.

5. After cleaning, reinstall the end cap and connect the pipe.

Change compressor oil

When the oil is turbid and unclear from the oil sight glass, the compressor oil needs to be replaced. The compressor oil has been changed once before the equipment leaves the factory, and it can be changed once a year from now on.

Charge refrigerant

When the equipment has low pressure protection or the ice making effect is not good, it depends on whether there is a refrigerant leak. Under normal circumstances, the high pressure of equipment operation is 12-14 kg, and the low pressure is 2-4 kg. If the low pressure pressure is lower than 2kg, it means that there is a leakage of refrigerant. Find out the leakage point and weld it in time. ) And charge refrigerant at the same time.

System charge refrigerant: When the refrigeration system is filled with refrigerant, the steel cylinder with qualified refrigerant should be weighed on the scale, make a record, and use the connecting pipe to connect with the unit injection valve (condenser, liquid storage) The high pressure of the tank is added at the same time), and the vacuum in the system is used to inject the refrigerant into the system. When the pressure in the system rises to 0.196~0.294MPa (2~3kgf/cm2), the system will be tested for leaks again. If it leaks, it should be repaired after the leak is found, and then filled with refrigerant. When the system pressure is the same as the cylinder pressure, the compressor can be started to increase the charging speed until it meets the refrigerant weight required by the system.

When charging refrigerant during startup, add it on the suction side of the compressor to ensure that it is refrigerant gas (Note: When charging refrigerant, you must ensure that R404 is a refrigerant liquid and needs to be reversed; when charging, pay attention to compressor suction On the other hand, according to the frosting condition of the compressor, determine to add refrigerant to avoid wet compression and damage the compressor. In order to avoid liquid hammer, it is best to add refrigerant from the condenser).

Check the line regularly

When the machine is running, always check whether the water solenoid valve can be closed normally, and regularly check whether the electric box and wiring are firm to ensure that there is no leakage or short circuit (a comprehensive inspection is done every 2-3 months).

Good maintenance of machinery and equipment plays a key role in the performance and life of the equipment. The ice machine equipment should be maintained and managed by full-time personnel (trained by our company's Bingquan Refrigeration). Customers should pay attention to the training of new personnel after the change of maintenance personnel to ensure the operation and maintenance of the tube ice machine.